SonoLume
pdfPDF Cut sheet
Pendant system (clouds) aluminum extrusion and equipped with acoustic panels engineered to provide optimal acoustic performance within interior environments. The acoustic panels are available in 1-inch thickness (NRC 0.90) and 2-inch thickness (NRC 0.95), and can be customized in various configurations to meet the designer’s specifications. Upholstery is available in a diverse selection of colors. Lighting options include direct (downlight) and indirect (LeeSti lighting module) illumination, both configurable according to the designer’s requirements. Factory-programmed drivers for the indirect linear lighting (LeeSti) enable adjustable light output. Downlights feature a 4-inch aperture with a diffuser lens, with drivers integrated into the housing. Drivers for linear fixtures are installed remotely, supporting a maximum distance of 60 feet. Fiberglass panels are finished with an acoustical fabric.
Product Image
archlit reserves the right to make changes without prior notice. (11.10.2025)
Pendant system (clouds) aluminum extrusion and equipped with acoustic panels engineered to provide optimal acoustic performance within interior environments. The acoustic panels are available in 1-inch thickness (NRC 0.90) and 2-inch thickness (NRC 0.95), and can be customized in various configurations to meet the designer’s specifications. Upholstery is available in a diverse selection of colors. Lighting options include direct (downlight) and indirect (LeeSti lighting module) illumination, both configurable according to the designer’s requirements. Factory-programmed drivers for the indirect linear lighting (LeeSti) enable adjustable light output. Downlights feature a 4-inch aperture with a diffuser lens, with drivers integrated into the housing. Drivers for linear fixtures are installed remotely, supporting a maximum distance of 60 feet. Fiberglass panels are finished with an acoustical fabric.
SoLume
Sound Light Direct Indirect
Output direct
NoDir - No Output direct
25 - 2,500 lumens 3000k 20w 350 mA
35 - 2,500 lumens 3500k 20w 350 mA

Finish Direct Lighting
WH - White
BK - Black
CU - Custom Color
Specify RAL color

Only trim

Location of Lighting Fixture
DoC - Downlight Center
DoCu - Downlight Custom
Specify Location in coordinates or drawing 0,0 is the upper view of the panel from above
NoDirLoc - No Downlight

Linear always at middle of panel length

Output Indirect
NoLin - No Linear Indirect Lighting
3017 - 3000 K 1200 lumens / ft 12 w /ft
3014 - 3000 K 1000 lumens / ft 10 w /ft
3011 - 3000 K 780 lumens / ft 7.5 w /ft
3008 - 3000 K 350 lumens / ft 5.5w /ft
3005 - 3000 K 500 lumens / ft 3.1 w /ft
3517 - 3500 K 1200 lumens / ft 12 w /ft
3514 - 3500 K 1000 lumens / ft 10 w /ft
3511 - 3500 K 780 lumens / ft 7.5 w /ft
3508 - 3500 K 560 lumens / ft 5.5w /ft
3505 - 3500 K 350 lumens / ft 3.1 w /ft

Use of programmable drivers allow different outputs (lumen output and load) in fix color temperature versions

Indirect Linear Lighting Length
NiL - No Indirect Linear
B - 2' nominal 22.78"
C - 3' nominal 34.75"
D - 4' nominal 46.75"
E - 5' nominal 57.25"
F - 6' nominal 69.25"
G - 7' nominal 79.75"
H - 8' nominal 91.75"

Panel Thickness
Th1 - 1" Thickness NRC 0.90
Th2 - 2" Thickness NRC 0.95

Panels Corners finish
90 - 90 degree finish
Rad - Radios finish 3/4" max

Finish of Fabric
CUFa - Acoustical material
Please select chart number Colors can have variations depending on screen settings

Custom Standard, specify color from chart at Custom finish

Panels width
PW2 - 2' nominal
PW3 - 3' nominal
PW4 - 4' nominal

Length by run choice, all panels in the same run will share the same width

Panels Length
PL2 - 2' nominal Length
PL3 - 3' nominal Length
PL4 - 4' nominal Length
PL5 - 5' nominal Length
PL6 - 6' nominal Length
PL7 - 7' nominal Length
PL8 - 8' nominal Length

Dimming
4 - Dimmable 0-10v (4wires, 120 or 277 v)
O - Non dimmable 120v
1 - Non dimmable 277v

Canopy
Sq - Square 4.25"
Rd - Round 4.25"

Suspension
36 - 36" max
100 - 100" max

Emergency
00 - No Emergency
EM - Emergency
Specify qty only if Emergency

Specify quantity of 4' nominal in runs if Indirect Linear
Emergency and driver remote, up to 50´
Use BWG 18 for connections
Max 4 feet Emergency per module indirect

Direct emergency remote. Max 30'

Notes:
McAdam 3 step binning
More than 90 CRI
Drivers remote
Max distance to drivers 60' for linear indirect component
1" panels NRC 0.90
2" panels NRC 0.95