AnCar 3 CeiWall
AnCar 3 CeiWall, wall and ceiling mounted, in extruded aluminum minimal design lighting fixture with remote drivers (max 60' from fixture).
AnCar 3 CeiWall powder coated finish with even illumination at highest lumen output. 960 lumens delivered per foot,12 w/foot. Dimmable and non dimmable. Lighting module width 3.25".
Trim and Trimless versions. Possible runs. Horizontal and / or vertical.
AnCar 3 CeiWall powder coated finish with even illumination at highest lumen output. 960 lumens delivered per foot,12 w/foot. Dimmable and non dimmable. Lighting module width 3.25".
Trim and Trimless versions. Possible runs. Horizontal and / or vertical.
AnCar 3 CeiWall
AnCar / Wall/Ceiling
archlit reserves the right to make changes without prior notice. (03.26.2026)
AnCar 3 CeiWall, wall and ceiling mounted, in extruded aluminum minimal design lighting fixture with remote drivers (max 60' from fixture).
AnCar 3 CeiWall powder coated finish with even illumination at highest lumen output. 960 lumens delivered per foot,12 w/foot. Dimmable and non dimmable. Lighting module width 3.25".
Trim and Trimless versions. Possible runs. Horizontal and / or vertical.
AnCar 3 CeiWall powder coated finish with even illumination at highest lumen output. 960 lumens delivered per foot,12 w/foot. Dimmable and non dimmable. Lighting module width 3.25".
Trim and Trimless versions. Possible runs. Horizontal and / or vertical.
AnCar3CeiWall
AnCar
3
CeiWall
AnCar3CeiWall
AnCar3CeiW -
Lumen Output
35HO - 3500 K 960 lumens / ft 12 w /ft
35 - 3500 K 640 lumens / ft 6 w /ft
40HO - 4000 K 960 lumens / ft 12 w /ft
40 - 4000 K 640 lumens / ft 6 w /ft
2700 K and 3000 K available for special ordering
Consult factory for other color temperatures
Finish
SA - Silver anodized aluminum
BK - Black
CU - Custom Specify RAL color
set up charges apply
Dimming
4 - Dimmable 0-10v (4wires, 120 or 277 v)
1 - Non Dimmable 277v
O - Non Dimmable 120v
Installation
Cei - Ceiling
Wa - Wall
Specify qty of vertical (wall) and horizontal (ceiling)
Runs
B - 2' nominal 23" LED module
C - 3' nominal 35 LED module
D - 4' nominal 47'' LED module
E - 5' nominal 59" LED module
F - 6' nominal 71" LED module
G - 7' nominal 83" LED module
H - 8' nominal 95" LED module
Total Run: (0 ft 0 in)
Runs lengths may result in light leaks between fixtures
Emergency
00 - No Emergency
EM - Emergency module max. 4'
Notes:
Drivers are Remote. max segment length 8'
Max distance to drivers 60'
CRI more than 90. McAdam 3 bin
Specify Qty of vertical (wall) and horizontal (ceiling)
Max distance to drivers 60'
CRI more than 90. McAdam 3 bin
Specify Qty of vertical (wall) and horizontal (ceiling)