ChriBa 2 Slots-
ChriBa 2 Slots, extruded aluminum minimal design lighting fixture with remote drivers (max 20' from fixture).
Powder-coated finish and diffuser for even illumination at highest lumen output. xx lumens delivered per foot,11 w/foot. Dimmable and non dimmable. Based on Armstrong WoodWorks linear solid wood panels and WoodWorks linear veneered panels. Lighting module width 1.75"".
Powder-coated finish and diffuser for even illumination at highest lumen output. xx lumens delivered per foot,11 w/foot. Dimmable and non dimmable. Based on Armstrong WoodWorks linear solid wood panels and WoodWorks linear veneered panels. Lighting module width 1.75"".
ChriBa 2 Slots-
ChriBa / Wall/Ceiling
archlit reserves the right to make changes without prior notice. (06.08.2026)
ChriBa 2 Slots, extruded aluminum minimal design lighting fixture with remote drivers (max 20' from fixture).
Powder-coated finish and diffuser for even illumination at highest lumen output. xx lumens delivered per foot,11 w/foot. Dimmable and non dimmable. Based on Armstrong WoodWorks linear solid wood panels and WoodWorks linear veneered panels. Lighting module width 1.75"".
Powder-coated finish and diffuser for even illumination at highest lumen output. xx lumens delivered per foot,11 w/foot. Dimmable and non dimmable. Based on Armstrong WoodWorks linear solid wood panels and WoodWorks linear veneered panels. Lighting module width 1.75"".
ChBa2Slo
ChriBa
2
Slots
Acronym of model
ChBa2Slo -
Please add at beginning of spec
Lumen Output Horizontal
H35 - Horizontal 3500 K 840 Lumens/foot 7.5 w/ f
H35HO - Horizontal 3500 K 1260 Lumen/foot 11 w/f
H40 - Horizontal 4000 K 840 lumen/foot 7.5 w/ f
H40HO - Horizontal 4000 K 1260 lumen/foot 11 w/f
NoH - No Horizontal
2700 K and 3000 K available for special ordering
Consult factory for other color temperatures
Max 8'nominal length with std output
HO max. length 5' nominal
Lumen Output Vertical
V35 - Vertical 3500 K 840 lumen/foot 7.5 w/ f
V35HO - Vertical 3500 K 1260 lumen/foot 11 w/f
V40 - Vertical 4000 K 840 lumen/foot 7.5 w/ f
V40HO - Vertical 4000 K 1260 lumen/foot 11 w/ f
NoV - No Vertical
2700 K and 3000 K available for special ordering
Consult factory for other color temperatures
Max 8'nominal length with std output
HO max. length 5' nominal
Horizontal Individual Modules
inB - Individual 2' nominal 24"
inC - Individual 3' nominal 35 7/8"
inD - Individual 4' nominal 47 5/8"
inE - Individual 5' nominal 59 3/8"
inF - Individual 6' nominal 71 3/8"
inG - Individual 7' nominal 83"
inH - Individual 8' nominal 94 7/8"
Vertical Individual Modules
VeB - Individual 2' nominal 24"
VeC - Individual 3' nominal 35 7/8"
VeD - Individual 4 nominal 47 5/8"
VeE - Individual 5' nominal 59 3/8"
VeF - Individual 6' nominal 71 3/8"
ViG - Individual 7' nominal 83"
VeH - Individual 8' nominal 94 7/8"
Finish
WH - White
BK - Black
CU - Custom Specify RAL color
set up charges apply
Runs Horizontal
NoHo - No Horizontal
EnHoRuB - End Horizontal Module 2' 23 7/8
InHoRuB - Intermediate Horizontal Run 2' 23 3/4"
EnHoRuC - End Horizontal Module 3' 35 3/4
EnHoRuC - Intermediate Horizontal Module 3' 35 5/8
EnHoRuD - End Horizontal Module 4' 47 1/2"
InHoRuD - Intermediate Horizontal Module 4' 47 3/8
EnHoRuE - End Horizontal Module 5' 591/4
InHoRuE - Intermediate Horizontal Module 5' 59 1/8
EnHoRuF - End Horizontal Module 6' 71 1/8"
InHoRuF - Intermediate Horizontal Module 6' 71
EnHoRuG - End Horizontal Module 7' 82 7/8
InHoRuG - Intermediate Horizontal Module 7' 82 3/4"
EnHoRuH - End Horizontal Module 8' 94 3/4
InHoRuH - Intermediate Horizontal Module 8' 94 5/8"
EnHoRuA - End Horizontal Module 1' 12 1/8"
Use only as filler
InHoRuA - Intermediate Horizontal Module 1' 12"
Use only as filler
Each run requires two end modules.
Runs lengths may result in light leaks between fixtures
Runs Vertical
EnVeRuB - End Vertical Module 2' 23 7/8
InVeRuB - Intermediate Vertical Run 2' 23 3/4"
EnVeRuC - End Vertical Module 3' 35 3/4
InVeRuC - Intermediate Vertical Module 3' 35 5/8
EnVeRuD - End Vertical Module 4' 47 1/2"
InVeRuD - Intermediate Vertical Module 4' 47 3/8
EnVeRuE - End Vertical Module 5' 591/4
InVeRuE - Intermediate Vertical Module 5' 59 1/8
EnVeRuF - End Vertical Module 6' 71 1/8"
InHoRuF - Intermediate Vertical Module 6' 71
EnVeRuG - End Vertical Module 7' 82 7/8
InVeRuG - Intermediate Vertical Module 7' 82 3/4"
EnVeRuH - End Vertical Module 8' 94 3/4
InVeRuH - Intermediate Vertical Module 8' 94 5/8"
EnVeRuA - End Horizontal Module 1' 12 1/8"
Use only as filler
InVeRuA - Intermediate Vertical Module 1' 12"
Use only as filler
Each run requires two end modules.
Runs lengths may result in light leaks between fixtures
Dimming
4 - Dimmable 0-10v (4wires, 120 or 277 v)
1 - Non Dimmable 277v
O - Non Dimmable 120v
Emergency
00 - No Emergency
EM - Emergency module max. 4'
Notes:
Drivers are Remote. max segment length 8'
Max distance to drivers 20'
CRI more than 90. McAdam 3 bin
Choice of runs, each run requires two end modules
Max distance to drivers 20'
CRI more than 90. McAdam 3 bin
Choice of runs, each run requires two end modules


























