LeeSti Adjustable Trimless Wall
LeeSti Adjustable Recessed Trimless Wall is a recessed linear lighting fixture in 1', 2' and 4' lengths. 3000 K and 2700 K color temperature
available. Integrated into standard walls of 4", with it's 3" depth allows to aim them to the ceiling or space. A diffusing film in the lens prevents
from seeing the lighting source dots (LED) generating a continuous line of light. Dimmable or non dimmable with 0-10v dimmers (0 to 10%)
with 4 wires to connect to control systems or Triac versions (0-1%) with 2 wires that can be used with standard dimmers. Drivers remote The
system is installed without tools, the lighting module is pushed up to install, pushed up to uninstall. Vertical or horizontal installation.
available. Integrated into standard walls of 4", with it's 3" depth allows to aim them to the ceiling or space. A diffusing film in the lens prevents
from seeing the lighting source dots (LED) generating a continuous line of light. Dimmable or non dimmable with 0-10v dimmers (0 to 10%)
with 4 wires to connect to control systems or Triac versions (0-1%) with 2 wires that can be used with standard dimmers. Drivers remote The
system is installed without tools, the lighting module is pushed up to install, pushed up to uninstall. Vertical or horizontal installation.
LeeSti Adjustable Trimless Wall
LeeSti / Wall
archlit reserves the right to make changes without prior notice. (05.11.2015)
LeeSti Adjustable Recessed Trimless Wall is a recessed linear lighting fixture in 1', 2' and 4' lengths. 3000 K and 2700 K color temperature
available. Integrated into standard walls of 4", with it's 3" depth allows to aim them to the ceiling or space. A diffusing film in the lens prevents
from seeing the lighting source dots (LED) generating a continuous line of light. Dimmable or non dimmable with 0-10v dimmers (0 to 10%)
with 4 wires to connect to control systems or Triac versions (0-1%) with 2 wires that can be used with standard dimmers. Drivers remote The
system is installed without tools, the lighting module is pushed up to install, pushed up to uninstall. Vertical or horizontal installation.
available. Integrated into standard walls of 4", with it's 3" depth allows to aim them to the ceiling or space. A diffusing film in the lens prevents
from seeing the lighting source dots (LED) generating a continuous line of light. Dimmable or non dimmable with 0-10v dimmers (0 to 10%)
with 4 wires to connect to control systems or Triac versions (0-1%) with 2 wires that can be used with standard dimmers. Drivers remote The
system is installed without tools, the lighting module is pushed up to install, pushed up to uninstall. Vertical or horizontal installation.
LEARW
LeeSti
Adjustable
Recessed
Trimless
Wall
Lumen Output
3017 - 3000 K 1200 lumens / ft 12 w /ft
3014 - 3000 K 1000 lumens / ft 10 w /ft
3011 - 3000 K 780 lumens / ft 7.5 w /ft
3008 - 3000 K 560 lumens / ft 5.5w /ft
3005 - 3000 K 350 lumens / ft 3.1 w /ft
3517 - 3500 K 1200 lumens / ft 12 w /ft
3514 - 3500 K 1000 lumens / ft 10 w /ft
3511 - 3500 K 780 lumens / ft 7.5 w /ft
3508 - 3500 K 560 lumens / ft 5.5w /ft
3505 - 3500 K 350 lumens / ft 3.1 w /ft
WhTu - White tuning 2700K @ 1050 lumens/foot and 6500k @1200 lumens/foot 12.5 watt/foot
All Uplight versions with light will have a transparent diffuser
Use of programmable drivers allow different outputs (lumen output
and load) to fix color temperature versions
Finish
WH - White
BK - Black
CU - Custom Color
Specify RAL color
Dimming Options
O - Non Dimmable 120v
1 - Non Dimmable 277v
4 - Dimmable 0-10v (4wires, 120/277 v)
Dimmable TRIAC (2 wires, max 25w, 120v)
requires more drivers if run is bigger than 2'
Runs
A - 1' module 12.5w/foot nominal 12 inches
Cut out 2 1/4'' x 13 1/8"
B - 2' module 25w nominal 23 3/4 inches
Cut out 2 1/4'' x 24 1/2''
C - 3' module nominal 35 inches
Cut out 2 1/4" x 35 3/4''
D - 4' module 50w nominal 46 inches
Cut out 2 1/4" x 46 3/4''
Total Run: (0 ft 0 in)
Emergency
00 - No Emergency
EM - Emergency
Adding emergency to a 4' means (2) drivers and (2) emergency packages if want all in emergency If 4' has 2' with emergency and 2' without it, will have (2) drivers and(1) emergency package
Notes:
Drivers remote
Max distance to remote drivers 100'
Runs of more than 4' can be accomplish, with
modules of 1', 2' , 3' and 4'
Max distance to remote drivers 100'
Runs of more than 4' can be accomplish, with
modules of 1', 2' , 3' and 4'