MRI LeeSti Trimless
LeeSti MRI Adjustable Recessed Trimless linear, with 3000K and 2700K color temperatures available. With it’s 3“ depth allows to aim to the ceiling or to the space. A diffusing film in the lens controls glare and prevents from seeing the lighting source, generating a continuous line of light. Dimmable or non dimmable with 0-10v dimmers (0 to 10%) with 4 wires to connect to control systems or Triac versions with 2 wires that can be used with standard dimmers. Developed for MRI environments, fixture with non ferric materials. Drivers must be at a remote location, shielded or in another room. Damp location listed.
MRI LeeSti Trimless
LeeSti / Recessed
archlit reserves the right to make changes without prior notice. (03.14.2016)
LeeSti MRI Adjustable Recessed Trimless linear, with 3000K and 2700K color temperatures available. With it’s 3“ depth allows to aim to the ceiling or to the space. A diffusing film in the lens controls glare and prevents from seeing the lighting source, generating a continuous line of light. Dimmable or non dimmable with 0-10v dimmers (0 to 10%) with 4 wires to connect to control systems or Triac versions with 2 wires that can be used with standard dimmers. Developed for MRI environments, fixture with non ferric materials. Drivers must be at a remote location, shielded or in another room. Damp location listed.
LMARTS
LeeSti
MRI
Recessed
Adjustable
Trimless
Lumen Output
3017 - 3000 K 1200 lumens / ft 12 w /ft
3014 - 3000 K 1000 lumens / ft 10 w /ft
3011 - 3000 K 780 lumens / ft 7.5 w /ft
3008 - 3000 K 560 lumens / ft 5.5w /ft
3005 - 3000 K 350 lumens / ft 3.1 w /ft
3517 - 3500 K 1200 lumens / ft 12 w /ft
3514 - 3500 K 1000 lumens / ft 10 w /ft
3511 - 3500 K 780 lumens / ft 7.5 w /ft
3508 - 3500 K 560 lumens / ft 5.5w /ft
3505 - 3500 K 350 lumens / ft 3.1 w /ft
WhTu - White tuning 2700K @ 1050 lumens/foot and 6500k @1200 lumens/foot 12.5 watt/foot
All Uplight versions with light will have a transparent diffuser
Use of programmable drivers allow different outputs (lumen output
and load) to fix color temperature versions
Finish
WH - White
BK - Black
CU - Custom Color
Specify RAL color
Dimming Options
O - Non Dimmable 120v
1 - Non dimmable 277v
4 - Dimmable 0-10v (4wires, 120 or 277 v)
Triac dimmers max, 2'. Longer modules need drivers in 2'
increments
Runs
A - 1' nominal module 12.5w 12''
Cut Out 3"x 13 1/8"
B - 2' nominal module 25w 23 3/4''
Cut Out 3" x 24 1/2"
C - 3' module 37.5 w nominal 35"
Cut Out 3"x 35 3/4"
D - 4' nominal module 50w 46"
Cut Out 3" x 46 3/4"
Total Run: (0 ft 0 in)
Emergency
00 - No emergency
EM - Emergency
Module max 24". Adding emergency. to a 4' means (2) drivers
and (2) emergency packages if want all in emergency. If 4' has
2' with emergency and 2' without it, will have (2) drivers and(1)
emergenc
Notes:
Drivers are remote
Max distance to drivers 100'
Max distance to drivers 100'


